Electric underfloor heating sizing
Choose the system for the subfloor and finish, calculate the free heated area, confirm the required output, then select a mat or cable that fits the real layout.
Do not match a mat to the room's total area or buy an oversized cable with the intention of shortening it.
START HERE
System type, output and coverage are separate decisions. Work through them in this order.
Question 01
Confirm whether the base is concrete, screed, tile backer board, timber or another approved construction.
Question 02
The heating system, cover layer, floor sensor and temperature limits must suit the complete finished build-up.
Question 03
Deduct permanent exclusions and clearances, then prove that the mat or cable route fits the available shape.
Question 04
Decide whether the system provides background comfort or must meet the room's calculated heat loss as the main emitter.
STEP 1
Obtain confirmation that the complete build-up is suitable. Approval of the finish alone does not automatically approve the adhesive, underlay, compound or substrate.
| Final finish or project | Common system route | Checks before selection |
|---|---|---|
| Tile or stone | Heating mat, loose cable or compatible cable/decoupling system | Subfloor stability, insulation, adhesive, output and minimum cable cover |
| Engineered wood or laminate | Foil system or another build-up approved for the finish | Floor-temperature limit, underlay, floating-floor instructions and moisture conditions |
| Vinyl or linoleum | Approved system beneath a smoothing layer or specified dry build-up | Manufacturer approval, temperature limit, flatness and minimum cover |
| Carpet | System approved for carpet and underlay | Combined thermal resistance or TOG, floor-temperature limit and output |
| Awkward or irregular room | Loose cable or cable/decoupling system may fit better | Cable spacing, perimeter clearances, fixed objects and layout drawing |
STEP 2
Measure from the route that can safely contain heating—not simply the external room dimensions.
Break an irregular room into rectangles, calculate each area and add them. A dimensioned sketch is more reliable than one length and width.
Deduct floor-level units, baths, trays, toilet pedestals, fitted cabinets, solid-base appliances, fireplaces and fixed objects that block heat dissipation.
Use the manual's clearances around walls, drains, heat sources and movement joints. Not every remaining centimetre is usable.
Prove that the mat can turn and pass between exclusions without crossing or bunching. Confirm the largest size that fits comfortably.
WORKED EXAMPLE
The 4.8m² gross area contains a 1.7m² bath plus 0.55m² of vanity and toilet exclusions. Layout clearances reduce the usable heating area further.
| Calculation | Result |
|---|---|
| Gross room area | 4.8m² |
| Fixed exclusions | 2.25m² |
| Remaining before clearances | 2.55m² |
| Practical free heated area after layout checks | Approximately 2.35m² |
STEP 3
Mat area describes coverage; watts per square metre describes installed output. Heat loss, insulation, floor construction, finish and room use determine the right choice.
STEP 4
A mat is quick in open rectangular areas. Loose cable provides more freedom around islands, sanitaryware and angled walls but requires accurate designed spacing.
| Choose a mat when… | Choose loose cable when… |
|---|---|
| The free heated area has broad, regular runs | The room has narrow passages or many exclusions |
| Speed and preset spacing are priorities | The layout needs flexible turns with approved spacing |
| A stocked mat size fits comfortably | No practical mat size fits without overlap |
FINAL CHECK
Moveable furniture on legs may be treated differently by each system. Keep the as-built cable layout so future owners know where heating is installed and where drilling is unsafe.
Electric system sizing
Answers about free area, oversized mats, multiple mats and output selection.
No. Measure only the free heated area and confirm the mat can be routed through it. Permanent units, sanitaryware and clearances reduce usable coverage.
You may cut carrier mesh to turn the mat if instructions allow it, but the heating cable must never be cut or shortened. Choose a smaller mat or more flexible cable system.
Yes in some designs, but each mat must fit safely and an electrician must verify combined load, thermostat rating, circuit and switching before installation.
No. Output must suit the finish, heat loss and control strategy. The highest output is not a substitute for insulation or room design.